THERMAL SYSTEM MORE FTA

Innovative floor, wall or ceiling radiant heating and cooling system. Low thickness, low inertia and high efficiency system.

Download the data sheet now Download the manual now

It is a radiant heating system with very low thickness, minimal thermal inertia and high efficiency.

MORE FTA is a revolutionary radiant panel, without screed and characterised by its very small overall dimensions, which allows the creation of finished systems in less than 35 mm thickness, including flooring.

Quick laying and immediate walkability are the peculiar characteristics of the MORE FTA panel: in the case of floor laying, the same work team can start laying the system and finish the flooring without waiting for the screed to dry (from 21 days upwards) and without the need to carry out the thermal shock compulsory for traditional systems (7 days minimum), thus avoiding dead times at the building site and making the flooring immediately practicable.

The panel is supplied already coupled with the upper aluminium layer, further reducing laying time. A key feature of the panel, MORE FTA also features thermal insulation under the pipe, to limit heat loss.

Thanks to its conformation and high mechanical resistance, the panel allows the floor to be laid directly on top of it, generally without the need for load-distributing elements.

MORE FTA RANGE

MORE FTA - Installation pitch 160 mm

MORE FTA - Installation pitch 80 mm


Thermal system more fta

Use

The MORE FTA panel is the ideal solution for new constructions, thanks to its very low thermal inertia and therefore reduced system adjustment times, which combines well with the high inertia of the building envelope and is also suitable for renovations and on mezzanines or in any case where there is a reduced room height.

Thanks to its installation flexibility, MORE FTA can also be installed on ceilings and false ceilings as well as on walls; in the latter case, the radiant panel is laid in adherence to the masonry and then covered with a plasterboard or gypsum fibre covering.

Technical information

Laying and advantages

01

Laying the piping

The panel has grooves in the EPS layer, which are designed to accommodate 16 mm diameter pipes of the RBM MORE PLUS (PE-RT Type II/EVOH/PE-RT) series 3968 or MORE 4L series 3969.

02

Advantages of the panel

  • No screed
  • Quick, easy to apply and immediately walkable (no need to wait for the cement screed to dry)
  • Minimum footprint (min. overall thickness 35 mm including flooring)
  • Very low thermal inertia of the system
  • Low weight
  • Versatility (allows ceramic or parquet finish tiles to be laid directly on the panel*)
  • Increased thermal resistance
  • Thermal insulation under pipe
*
Field required
*
Field required
*
Field required
*
Field required
*
Field required
Field required